Having trouble viewing this email? View this page in your browser.

Instrument Design Technology Ltd

Newsletter - December 09


Product focus: Small KB Mirror System*


Our Small KB Mirror system has completed over a year's successful operation on the ID5 Microspectroscopy Beamline at the Australian Synchrotron, Melbourne. Highlights include:

Small KB Mirror System
  • Sub-micron beam spot size with mirror lengths of 240mm for HFM & VFM
  • Striped mirrors with translation mechanism
  • Sub-micron RMS spot position stability during multi-hour beam operation
  • Actuators with sub-micron repeatability
  • Simple alignment procedure to beamline reference frame
  • Simple focus to sub-micron spot size in minutes
  • Repeatable focus parameters after homing drives
  • Flexible design to accommodate a range of mirror geometries and hence sample positions
  • Helium environment

Wire scan results demonstrating a repeatable and highly stable 365nm x 660nm sigma focused spot size at the sample position. SSA (50μm x 700μm).IDT are pleased to offer this exciting system with:-

  • Low cost of ownership & ease of setup
  • Various mirror lengths up to a maximum of 320mm
  • Multi mirror coatings; Si, Pt, Cr etc
  • Helium & high vacuum environments
  • Motion control system including EPICS support

See our product datasheet for full details, or contact us for more information.

* Developed by IDT with a grant from the UK North West Development Agency.

News Update: SRI 09


Delegates attending the recent SRI conference held in Melbourne, Australia had the opportunity to view two IDT-built beamlines during a tour of the Australian Synchrotron:

High heat load slitsIDT recently completed the Imaging and Medical beamline with very high heat load slits & filters plus photon stop mechanisms. The beamline has just welcomed its first users. See our datasheet for full details.

With over a year of outstanding operation, ID5-Microspectroscopy beamline was designed, built & performance demonstrated by IDT. ID5 has a novel optics layout with a horizontally deflecting cryo-cooled DCM with 2 sets of crystals plus a secondary source aperture (sub-micron accuracy H & V slits). See datasheet for full details of the ID5 beamline optics and performance.

Design Studies


IDT is highly skilled at design studies for new beamlines covering:-

Design Studies
  • Optical scheme studies
  • Ray tracing
  • FEA of optics & systems
  • Vacuum schemes
Read more

Tables


Multi DOF table IDT has supplied multi degree-of-freedom tables to various SR facilities, including Swiss Light Source, Diamond, DESY-Petra III, APS.

Read more